Vent-A-Hood blower jumping to full power by itself: SensaSource has sensed heat

Vent-A-Hood fits a heat sensor called SensaSource to the two-speed Magic Lung blower on its red rocker switch.

(844) 398-3217

Mon–Sat, 8am–8pm

  • Mode, not a failure
  • No repair needed
  • Source: Vent-A-Hood

Book a visit

Three short steps, about a minute.

or call (844) 398-3217

What Blower jumps from LOW to full power
actually means.

Vent-A-Hood fits a heat sensor called SensaSource to the two-speed Magic Lung blower on its red rocker switch. When that blower is set to LOW and the heat inside the canopy climbs past its limit, or flames reach the hood, the sensor pushes the blower to full power on its own and lets it drop back to LOW once the heat falls. A Vent-A-Hood has no display, so this change in sound is the only signal it gives.

Vent-A-Hood range hood display · also shown as SensaSource, fan speeds up by itself, red switch hood runs on high

What to do when Blower jumps from LOW to full power shows on the range hood

Before you book,
in this order.

Each step comes from Vent-A-Hood's own guidance for Blower jumps from LOW to full power on its range hoods. Follow it to the end: the last card says whether this is a visit.

01

Look at the burners first: if there is flame in a pan or reaching toward the hood, turn the burner off, slide a lid over the pan and leave it, never use water, and get out and call 911 if fire gets into the hood or a cabinet.

02

If it is only hard searing or several burners on high, leave the blower running; it should settle back to LOW a few minutes after the heat comes down.

03

To stop the fan early, move the red rocker to its middle OFF position once the pans are off the heat.

04

If the blower races on a cold hood, or will not leave full power after everything has cooled, book a visit so the sensor and the switch can be tested.

Cleared?

The code is gone and the blower pulls steam up on every speed again without a new part. If it returns this week, or the filter reminder keeps coming back right after a cleaning, mention it in the booking.

What not to do

The jump to full power is not a motor about to fail, and it only concerns the two-speed blower on the red switch. The extra single-speed blower on a black switch is never run by SensaSource, so a black-switch blower that stops or races points somewhere else.

No repair indicated

Nothing to repair.

The hood is doing something it was told to do, not wearing out: a delay-off timer that keeps the blower running for some minutes after the burners go off, a heat sentry that starts the fan by itself when it senses a hot pan, a Sabbath setting that locks the keys and dims the lights, or a link to the cooking surface that sets the speed on its own. No part is needed; a key sequence from the manual, or simply waiting, ends it.

In Vent-A-Hood's own words

If the heat reaches an unacceptable level inside the hood, or a range fire occurs
Vent-A-Hood Owner and Maintenance Guide for models with the Magic Lung blower (L023) Vent-A-Hood Owner and Maintenance Guide for models with the Magic Lung blower (L023) Vent-A-Hood Owner and Maintenance Guide for models with the Magic Lung blower (L023) Vent-A-Hood Technologies page

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Magic Lung hoods with rocker switches (red, white and black) carry SensaSource on the two-speed blower. Hoods with dial controls switch each blower separately and the guide does not describe a sensor on them.

Vent-A-Hood Blower jumps from LOW to full power range hood repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A family cooking together under a stainless range hood in a bright kitchen.
For the heart of your home.

Questions
about Blower jumps from LOW to full power.

Can I clear Blower jumps from LOW to full power myself?
Look at the burners first: if there is flame in a pan or reaching toward the hood, turn the burner off, slide a lid over the pan and leave it, never use water, and get out and call 911 if fire gets into the hood or a cabinet.
Why does my Vent-A-Hood suddenly get loud while I sear a steak?
The SensaSource sensor on the two-speed blower has felt enough heat in the canopy to switch from LOW to full power. It drops back to LOW by itself once the pan cools or comes off the burner.
Can I turn SensaSource off on a Vent-A-Hood?
Vent-A-Hood's guide does not give an owner setting to disable it. You can still turn the blower off with the red switch in its middle position, which is the normal way to stop the fan after cooking.
My Vent-A-Hood runs at full power with nothing cooking. Is that the sensor?
SensaSource should only react to heat, so full power on a cold hood suggests the sensor or the rocker switch is misreading. That is worth a visit, because the blower can wear faster running flat out all the time.