Under-cabinet range hood installation runs in a set order: choose the exhaust route and open its knockout, mark and cut the cabinet, fit the damper so it opens with the airflow, hang the hood on its mounting screws, then connect the cable in the wiring box with the breaker off. The manual's template decides every dimension.

By [RangeHoodeRepair.center technical team](https://rangehooderepair.center/authors/technical-team/) Published November 21, 2026

## At a glance.

An under-cabinet hood looks like a one-afternoon job, and most of it is: marking, cutting, hanging and connecting. The steps that go wrong are the quiet ones, a knockout opened on the wrong side or a damper turned the wrong way, and they show up weeks later as noise or drafts.

Read the whole guide

### Template the paper pattern in the carton

it sets the duct, screw and cable positions

### Damper the flap opens with the airflow

and falls shut when the fan stops

### Duct metal, at the diameter in the manual

foil tape on seams, no cloth tape

### Wiring an electrician connects it with the breaker off

following the hood's wiring diagram

In this guide

1. Where does the air leave, and which knockout do you open?
2. How do you mark and cut the cabinet?
3. Which way does the damper face?
4. How is the hood hung and wired?
5. Step by step
6. Questions

## Where does the air leave, and which knockout do you open?

The air leaves through whichever opening matches your duct route, and the hood has a stamped knockout for each one. Choose the route first, because the cabinet cut depends on it.

### Top or back discharge

An under-cabinet hood typically offers a round or rectangular opening on the top, and often a second one on the back. Top discharge goes up through the cabinet above and then to the attic or an outside wall; back discharge goes straight into the wall behind. Pick the shorter route with the fewest elbows, since every bend takes airflow away.

### Opening the knockout

Use the knockout your route needs and leave the others closed. Score around the stamped tab with tin snips or flex it back and forth until it detaches, and wear gloves because the edge is sharp. If the hood will recirculate instead, no knockout is opened, and the guide on a [convertible range hood](https://rangehooderepair.center/guides/convertible-range-hood-meaning/) lists what that setup needs.

## How do you mark and cut the cabinet?

You mark from the paper template in the carton, not from measurements taken by eye.

- Tape the template to the underside of the cabinet, lined up with the front edge and centered over the stove.
- Mark the duct opening, the screw positions and the cable entry.
- Drill a small pilot hole at each corner of the duct opening before you cut anything.
- Check from above that nothing in the cabinet, such as a shelf support or a pipe chase, sits in the cut.

### Cutting the opening

Drill the corners, then cut between them with a jigsaw or a hole saw sized to the duct. Cut on the waste side of the line and clean the edge, since the transition needs a flat seat. Wear eye protection and keep a vacuum at hand; wood dust falls on the stove.

### Hanging height

The manual gives the allowed distance between the stove surface and the underside of the hood. The two numbers that matter are the minimum above the burners, to keep heat off the hood, and the maximum, to keep it catching smoke. Read both before you commit to the screws.

A close view of the underside of a wall cabinet with a marked rectangle for the duct cut, pencil lines and a drill with a small bit beside it.

## Which way does the damper face?

The damper's flap opens in the direction the air travels, away from the hood, and falls closed when the fan stops.

Check the arrow or the hinge: the flap should lift away from the hood when air pushes it and drop closed when the fan stops. Before you fit it, test three things:

- the flap moves freely by hand and nothing in the collar blocks it
- the arrow or hinge side points toward the outside
- it seats flat in the collar with no gap that lets air leak around it

If it goes in backwards, the flap sits pinned open or shut, the fan sounds strangled and cold air comes back down the duct. Our guide to [duct runs and the backdraft damper](https://rangehooderepair.center/guides/duct-runs-and-the-backdraft-damper/) shows what a healthy one does.

### Duct joints

Use metal duct of the diameter the manual specifies, joined with the crimped end of each piece pointing the way the air travels. Seal seams with foil tape, not cloth duct tape, and end in a wall or roof cap with its own damper. If a damper later sticks or the run needs changing, the [damper and duct repair](https://rangehooderepair.center/services/range-hood-damper-and-duct-repair/) service handles it.

## How is the hood hung and wired?

The hood hangs on screws into the cabinet bottom or on keyhole slots that take screws first, and the wiring box is connected last, by an electrician, with the breaker off.

### Support screws

Drive the screws through the mounting holes in the hood's flange into solid cabinet wood, using the length the manual states so that the point does not come through the cabinet's top surface or the face of a shelf above. Hang the hood on the screws partway driven, check that it is level front to back and side to side, and tighten. A hood hung only on thin cabinet material can sag, and the symptom described in [a hood pulling away from the wall](https://rangehooderepair.center/guides/a-hood-pulling-away-from-the-wall/) starts there.

### The wiring box

The house cable enters the hood's wire cover through a clamp and is joined to the hood's leads and ground as the wiring diagram shows. That connection is for an electrician: the circuit has to be switched off and proven dead, the cable has to be in good condition and grounded, and local rules may require a permit. Have the cable end left where the template's cable entry sits, so the hood can be hung over it. A hood that stays dark after hookup is covered in [the fan not working page](https://rangehooderepair.center/problems/range-hood-fan-not-working/).

### Setting the airflow limit

Some hoods carry a selector, jumper or setting that caps the top airflow for houses that need make-up air above a certain level. If your hood has one, set it at installation. [Make-up air for a strong hood](https://rangehooderepair.center/guides/make-up-air-for-a-strong-hood/) explains when that matters, and [sizing a hood and its airflow](https://rangehooderepair.center/guides/sizing-a-hood-and-its-airflow/) covers the choice of size.

## Where to stop

The wiring box is an electrician's job, and so is any cable that is old, cloth-covered, aluminum or ungrounded, or a circuit shared with something you cannot identify. Cutting a new exterior wall or roof opening, and anything near a gas line or gas stove connection, goes to a contractor or a qualified installer. A hood that hangs crooked after tightening needs its cabinet checked.

Written by [RangeHoodeRepair.center technical team](https://rangehooderepair.center/authors/technical-team/). The crew that fixes kitchen range hoods here, writing from its own service visits and each maker's installation papers.

## Step by step.

Four steps, in the order worth doing them.

01

### Pick the route and open one knockout

Choose the shortest path outside and open only the knockout that matches it.

02

### Mark and cut the cabinet

Tape the template, drill pilot holes, check the cabinet above, then cut the duct opening.

03

### Fit the damper and duct

Seat the damper so the flap opens with the airflow, then join metal duct with foil tape.

04

### Hang the hood and wire it

Drive the support screws, level the hood, and have an electrician connect the cable with the breaker off.

For the heart of your home.

## Questions owners ask.

### How high should an under-cabinet range hood be above the stove?

The manual for your hood gives a minimum and a maximum distance between the stove surface and the underside of the hood. The minimum keeps heat off the hood and the maximum keeps it capturing smoke. Measure from the cooking surface and use the numbers printed for your model, not a general figure.

### Do I have to duct an under-cabinet hood outside?

No, many models can recirculate through charcoal filters. The air is then returned to the room, so heat and steam stay. A duct to the outside clears more, and it is the better choice whenever a short route exists. A recirculating hood needs no knockout opened.

### Can I install the hood without cutting the cabinet?

If you recirculate or use a back discharge straight into the wall, you may not need to cut the cabinet. A top discharge through the cabinet needs an opening cut in its floor and top. Check the route against the template before you pick the model.

### Can I wire a range hood myself?

Leave it to an electrician. The circuit must be off and proven dead, the cable sound and grounded, and the joins made to the hood's diagram, and local rules may require a permit. You can do the marking, cutting and duct work around it. A diagnostic visit can check a hood that does not run after installation.

## The problems behind it.

Each has a page of its own: what it usually means and the causes in the order worth checking.

[All 17 problems](https://rangehooderepair.center/problems/)

Problem

### Range Hood Fan Not Working at Any Speed

6 causes, cheapest first

Stop cooking under it

### Range Hood Pulling Away From the Wall or Ceiling

6 causes, cheapest first

## When it needs a technician.

The repairs on the right are where this guide ends when the checks do not settle it.

### Range hood damper and duct repair

Getting the air out of the house: the backdraft damper, the duct and its joints, the wall or roof cap, and make-up air in a tight house.

### Range hood diagnostic visit

A visit that runs the hood through every speed and light, tests the draw at the filters and follows the air outside until one part is named.

## More in installation and setup.

Sizing a hood to the burners below, running the duct and fitting the backdraft damper, recirculating when no duct can reach outside, and the make-up air a strong blower needs in a tight house.

[The whole section](https://rangehooderepair.center/guides/installation-and-setup/)

Size, duct, damper and make-up air

### Sizing a Range Hood: Width, Mounting Height and CFM for Wall and Island

HVI's 100 and 150 CFM per foot, a canopy that covers the burners, the height windows makers print, and the duct a rating depends on.

Size, duct, damper and make-up air

### Range Hood Duct Runs and the Backdraft Damper: Size, Elbows and the Cap Outside

Smooth metal at full diameter, five feet for every elbow, where a duct may and may not end, and how a flap that sticks lets in cold air or chokes the fan.

Size, duct, damper and make-up air

### Make-Up Air for a Strong Range Hood: The 400 CFM Line and What It Protects

Why a tight house fights a big blower, the code line above 400 CFM, backdrafting gas flues, where the intake goes and who sizes and tests it.

Guides

### All 22 guides

Six sections, by what you are trying to find out.

---

**[Read on the site: Under-cabinet range hood installation: cabinet cut, duct, wiring](https://rangehooderepair.center/guides/under-cabinet-range-hood-installation/)**

**[Book a visit with RangeHoodeRepair.center](https://rangehooderepair.center/schedule/)**